48V 100AH ENERGY STORAGE
    Publish time 2017-06-06 11:22    

48V 100AH

48V 100AH ENERGY STORAGE



Basic Characteristics
Cell Parameters
No.
Item
Condition
Specification
1
Nominal Capacity
1C discharge capacity
6Ah
2
AC Internal Resistance
At 1000 Hz

≤8mΩ

3
Nominal Voltage
N/A
3.2V
4
Dimension
N/A

Φ(32.0±0.5) x H(70.2±0.4)mm

5
Weight
N/A
144g
6
Charge Cut-off Voltage
CC charge
3.65V
7
Charge Cut-off Current
CC Charge
≤0.3A
8
Charge Method
Standard charge
≤0.5C at CC/CV
9
Discharge Cut-off Voltage
CC discharge
2.0V
10
Max. Continuous Discharge Current
N/A
18A with 25˚C
11
Peak Discharge Current
N/A
60A within 3sec
12
Cycle Life Time
1C/ 100% DoD
≥2000 cycles
13Working Temperature
Charging
0 ~ 60˚C
Discharging
-20˚C ~ 60˚C
Storage
-20˚C ~ 25˚C

Battery Pack Parameters
5KWh 51.2V 100Ah LiFePO4
No.
Item
Specification
Remark
1
Composition
16S18P
N/A
2
Nominal Capacity
100AH
N/A
3
AC Internal Resistance
≤50mΩN/A
4
Nominal Voltage
51.2V
N/A
5
Cabinet Dimesion (L x W x H)
483 x 420 x 222mm
Exclude Connector and handles
6
System Rack Dimesion (L x W x H)600 x 600 x 422mm
Optional
7
Weight
58KG
N/A
8
Charging Cut-off Voltage
58.4V
N/A
9
Charging Cut-off Current
≤5A
N/A
10
Charging Condistions
≤1C at CC/CV
N/A
11
Discharging Cut-off Voltage
40V
N/A
12
Max. Cont-discharging Current
100A
N/A
13
Cycle Life Time
≥4000 cycles
0.5C / 80% DoD
14
Charging Current Limiting
0A
N/A
15Balancing Function
Start voltage: 3.38V
Start voltage difference: 30mV
16
Communication
RS485 for parallel connection, duble RS485/RS232/CAN
17
Main Functions

Protection for over charge, over discharge, over temperature,

over current, short circuit, LED status indicator, precharging,

charging balancing, charging current limiting function, with display

18
Working Charging
0˚C ~ 60˚C
19
Temperature of Discharging
-20˚C ~ 60˚C
20
Temperature of Storage
0˚C ~ 45˚C
21
System Capacity
Max. 15 batteries connected in parallel
22
Certificat

IEC62619 for 5KWh / 10KWH / 15KWh / 20 KWh, CE, RoHS,

UN38.3, MSDS for 5KWh.